Home Tools
Log in
Cart

Alobresib

Catalog No. T8495   CAS 1637771-14-2
Synonyms: Vorolanib, GS-5829

Alobresib (Vorolanib) is an inhibitor of BET bromodomain,is an antineoplastic drug candidate.

All products from TargetMol are for Research Use Only. Not for Human or Veterinary or Therapeutic Use.
Alobresib Chemical Structure
Alobresib, CAS 1637771-14-2
Pack Size Availability Price/USD Quantity
1 mg In stock $ 67.00
2 mg In stock $ 94.00
5 mg In stock $ 147.00
10 mg In stock $ 289.00
25 mg In stock $ 563.00
50 mg In stock $ 793.00
100 mg In stock $ 1,090.00
1 mL * 10 mM (in DMSO) In stock $ 162.00
Bulk Inquiry
Get quote
Select Batch  
Purity: 98.87%
Contact us for more batch information
Biological Description
Chemical Properties
Storage & Solubility Information
Description Alobresib (Vorolanib) is an inhibitor of BET bromodomain,is an antineoplastic drug candidate.
In vitro in vitro experiments demonstrated high sensitivity of USC cell lines to the exposure to GS-5829, GS-626510, and JQ1 with BET inhibitors causing a dose-dependent decrease in the phosphorylated levels of c-Myc and a dose-dependent increase in caspase activation (apoptosis).
In vivo In comparative in vivo experiments, GS-5829 and/or GS-626510 were found more effective than JQ1 at the concentrations/doses used in decreasing tumor growth in both USC-ARK1 and USC-ARK2 mouse xenograft models
Synonyms Vorolanib, GS-5829
Molecular Weight 437.49
Formula C26H23N5O2
CAS No. 1637771-14-2

Storage

Powder: -20°C for 3 years | In solvent: -80°C for 1 year

Solubility Information

DMSO: 27.5 mg/mL (62.86 mM)

TargetMolReferences and Literature

1. Bonazzoli E, et al. Inhibition of BET Bromodomain Proteins with GS-5829 and GS-626510 in Uterine Serous Carcinoma, a Biologically Aggressive Variant of Endometrial Cancer. Clin Cancer Res. 2018 Oct 1;24(19):4845-4853.

Related compound libraries

This product is contained In the following compound libraries:
Anti-Cancer Active Compound Library Inhibitor Library Anti-Cancer Clinical Compound Library Drug Repurposing Compound Library Anti-Cancer Drug Library Glutamine Metabolism Compound Library Epigenetics Compound Library Stem Cell Differentiation Compound Library Bioactive Compounds Library Max PPI Inhibitor Library

Related Products

Related compounds with same targets
SMD-3040 PLX51107 BET-IN-17 ABBV-744 PBRM1-BD2-IN-8 ICG-001 Piflufolastat (+)-JQ-1

TargetMolDose Conversion

You can also refer to dose conversion for different animals. More

TargetMol In vivo Formulation Calculator (Clear solution)

Step One: Enter information below
Dosage
mg/kg
Average weight of animals
g
Dosing volume per animal
ul
Number of animals
Step Two: Enter the in vivo formulation
% DMSO
%
% Tween 80
% ddH2O
Calculate Reset

TargetMolCalculator

Molarity Calculator
Dilution Calculator
Reconstitution Calculation
Molecular Weight Calculator
=
X
X

Molarity Calculator allows you to calculate the

  • Mass of a compound required to prepare a solution of known volume and concentration
  • Volume of solution required to dissolve a compound of known mass to a desired concentration
  • Concentration of a solution resulting from a known mass of compound in a specific volume
See Example

An example of a molarity calculation using the molarity calculator
What is the mass of compound required to make a 10 mM stock solution in 10 ml of water given that the molecular weight of the compound is 197.13 g/mol?
Enter 197.13 into the Molecular Weight (MW) box
Enter 10 into the Concentration box and select the correct unit (millimolar)
Enter 10 into the Volume box and select the correct unit (milliliter)
Press calculate
The answer of 19.713 mg appears in the Mass box

X
=
X

Calculator the dilution required to prepare a stock solution

Calculate the dilution required to prepare a stock solution
The dilution calculator is a useful tool which allows you to calculate how to dilute a stock solution of known concentration. Enter C1, C2 & V2 to calculate V1.

See Example

An example of a dilution calculation using the Tocris dilution calculator
What volume of a given 10 mM stock solution is required to make 20ml of a 50 μM solution?
Using the equation C1V1 = C2V2, where C1=10 mM, C2=50 μM, V2=20 ml and V1 is the unknown:
Enter 10 into the Concentration (start) box and select the correct unit (millimolar)
Enter 50 into the Concentration (final) box and select the correct unit (micromolar)
Enter 20 into the Volume (final) box and select the correct unit (milliliter)
Press calculate
The answer of 100 microliter (0.1 ml) appears in the Volume (start) box

=
/

Calculate the volume of solvent required to reconstitute your vial.

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial.
Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

g/mol

Enter the chemical formula of a compound to calculate its molar mass and elemental composition

Tip: Chemical formula is case sensitive: C10H16N2O2 c10h16n2o2

Instructions to calculate molar mass (molecular weight) of a chemical compound:
To calculate molar mass of a chemical compound, please enter its chemical formula and click 'Calculate'.
Definitions of molecular mass, molecular weight, molar mass and molar weight:
Molecular mass (molecular weight) is the mass of one molecule of a substance and is expressed n the unified atomic mass units (u). (1 u is equal to 1/12 the mass of one atom of carbon-12)
Molar mass (molar weight) is the mass of one mole of a substance and is expressed in g/mol.

bottom

Tech Support

Please see Inhibitor Handling Instructions for more frequently ask questions. Topics include: how to prepare stock solutions, how to store products, and cautions on cell-based assays & animal experiments, etc.

Keywords

Alobresib 1637771-14-2 Chromatin/Epigenetic Epigenetic Reader Domain GS 5829 Inhibitor GS5829 Vorolanib inhibit GS-5829 inhibitor

 

TargetMol