Home Tools
Log in
Cart

EB Eraser

Catalog No. TD0006   CAS TD0006

The strong EB detoxification agent is specially designed to remove the contaminated product of Ethidium bromide (EB).It can effectively destroy the structure of EB, remove the carcinogenicity of EB, so as to achieve the purpose of cleaning EB pollution.It is suitable for removing EB contamination on electrophoresis buffer, biochemical solution and solid surface (such as laboratory bench, centrifuge, glassware, stainless steel products, etc.).Using strong EB disinfectant to treat EB pollutants and then discard them can protect the environment from EB pollutants.

All products from TargetMol are for Research Use Only. Not for Human or Veterinary or Therapeutic Use.
EB Eraser Chemical Structure
EB Eraser, CAS TD0006
Pack Size Availability Price/USD Quantity
100 mg Inquiry Inquiry
500 mg Inquiry Inquiry
Bulk Inquiry
Get quote
Contact us for more batch information
Biological Description
Chemical Properties
Storage & Solubility Information
Description The strong EB detoxification agent is specially designed to remove the contaminated product of Ethidium bromide (EB).It can effectively destroy the structure of EB, remove the carcinogenicity of EB, so as to achieve the purpose of cleaning EB pollution.It is suitable for removing EB contamination on electrophoresis buffer, biochemical solution and solid surface (such as laboratory bench, centrifuge, glassware, stainless steel products, etc.).Using strong EB disinfectant to treat EB pollutants and then discard them can protect the environment from EB pollutants.
In vitro Clean up contaminated solution (100 ml EB contaminated solution)
Dilute contaminated solutions to meet the required concentration (≤0.5 mg/ml). In the fume hood, dilute 2 ml solution A to the final volume of 20 ml with deionized water, and dissolve 0.42 g of disinfectant B in water and fix the volume to 12 ml. Add solution A and disinfectant B working solution to 100 ml EB contaminated solution, stir and mix carefully (pH ≤ 3). After 24 hours of reaction at room temperature, the pH of contaminated solution was adjusted to 5-9 with sodium bicarbonate. A large amount of water is used to wash the reactants into the water tank.
Molecular Weight N/A
CAS No. TD0006

Storage

keep away from direct sunlight

Powder: -20°C for 3 years | In solvent: -80°C for 1 year

TargetMolDose Conversion

You can also refer to dose conversion for different animals. More

TargetMol In vivo Formulation Calculator (Clear solution)

Step One: Enter information below
Dosage
mg/kg
Average weight of animals
g
Dosing volume per animal
ul
Number of animals
Step Two: Enter the in vivo formulation
% DMSO
%
% Tween 80
% ddH2O
Calculate Reset

TargetMolCalculator

Molarity Calculator
Dilution Calculator
Reconstitution Calculation
Molecular Weight Calculator
=
X
X

Molarity Calculator allows you to calculate the

  • Mass of a compound required to prepare a solution of known volume and concentration
  • Volume of solution required to dissolve a compound of known mass to a desired concentration
  • Concentration of a solution resulting from a known mass of compound in a specific volume
See Example

An example of a molarity calculation using the molarity calculator
What is the mass of compound required to make a 10 mM stock solution in 10 ml of water given that the molecular weight of the compound is 197.13 g/mol?
Enter 197.13 into the Molecular Weight (MW) box
Enter 10 into the Concentration box and select the correct unit (millimolar)
Enter 10 into the Volume box and select the correct unit (milliliter)
Press calculate
The answer of 19.713 mg appears in the Mass box

X
=
X

Calculator the dilution required to prepare a stock solution

Calculate the dilution required to prepare a stock solution
The dilution calculator is a useful tool which allows you to calculate how to dilute a stock solution of known concentration. Enter C1, C2 & V2 to calculate V1.

See Example

An example of a dilution calculation using the Tocris dilution calculator
What volume of a given 10 mM stock solution is required to make 20ml of a 50 μM solution?
Using the equation C1V1 = C2V2, where C1=10 mM, C2=50 μM, V2=20 ml and V1 is the unknown:
Enter 10 into the Concentration (start) box and select the correct unit (millimolar)
Enter 50 into the Concentration (final) box and select the correct unit (micromolar)
Enter 20 into the Volume (final) box and select the correct unit (milliliter)
Press calculate
The answer of 100 microliter (0.1 ml) appears in the Volume (start) box

=
/

Calculate the volume of solvent required to reconstitute your vial.

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial.
Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

g/mol

Enter the chemical formula of a compound to calculate its molar mass and elemental composition

Tip: Chemical formula is case sensitive: C10H16N2O2 c10h16n2o2

Instructions to calculate molar mass (molecular weight) of a chemical compound:
To calculate molar mass of a chemical compound, please enter its chemical formula and click 'Calculate'.
Definitions of molecular mass, molecular weight, molar mass and molar weight:
Molecular mass (molecular weight) is the mass of one molecule of a substance and is expressed n the unified atomic mass units (u). (1 u is equal to 1/12 the mass of one atom of carbon-12)
Molar mass (molar weight) is the mass of one mole of a substance and is expressed in g/mol.

bottom

Tech Support

Please see Inhibitor Handling Instructions for more frequently ask questions. Topics include: how to prepare stock solutions, how to store products, and cautions on cell-based assays & animal experiments, etc.

Keywords

EB Eraser TD0006 inhibitor inhibit

 

TargetMol