Shopping Cart
  • Remove All
  • TargetMol
    Your shopping cart is currently empty

ICAAc

😃Good
Catalog No. T36843

ICAAc is a solvatochromic fluorescent pH probe.1 As the polarity of the solvent increases, the emission wavelength of ICAAc increases. It displays excitation/emission maxima of 466/553, 431/515, and 418/503 nm in water, dioxane, and hexane, respectively. The absorption maximum of ICAAc decreases with increasing pH. It displays absorption/emission maxima of 470/554 and 428/553 nm at pH 3 and 11, respectively, in aqueous Britton-Robinson buffer, and the fluorescence intensity increases as pH decreases. ICAAc can be used for live cell applications.

ICAAc

ICAAc

😃Good
Catalog No. T36843
ICAAc is a solvatochromic fluorescent pH probe.1 As the polarity of the solvent increases, the emission wavelength of ICAAc increases. It displays excitation/emission maxima of 466/553, 431/515, and 418/503 nm in water, dioxane, and hexane, respectively. The absorption maximum of ICAAc decreases with increasing pH. It displays absorption/emission maxima of 470/554 and 428/553 nm at pH 3 and 11, respectively, in aqueous Britton-Robinson buffer, and the fluorescence intensity increases as pH decreases. ICAAc can be used for live cell applications.
Pack SizePriceAvailabilityQuantity
5 mg166 €35 days
10 mg278 €35 days
25 mg568 €35 days
Bulk & Custom
Add to Cart
Questions
View More
Contact us for more batch information
Resource Download
All TargetMol products are for research purposes only and cannot be used for human consumption. We do not provide products or services to individuals. Please comply with the intended use and do not use TargetMol products for any other purpose.

Product Introduction

Bioactivity
Description
ICAAc is a solvatochromic fluorescent pH probe.1 As the polarity of the solvent increases, the emission wavelength of ICAAc increases. It displays excitation/emission maxima of 466/553, 431/515, and 418/503 nm in water, dioxane, and hexane, respectively. The absorption maximum of ICAAc decreases with increasing pH. It displays absorption/emission maxima of 470/554 and 428/553 nm at pH 3 and 11, respectively, in aqueous Britton-Robinson buffer, and the fluorescence intensity increases as pH decreases. ICAAc can be used for live cell applications.
|1. Nagy, M., Racz, D., Nagy, Z.L., et al. Amino-isocyanoacridines: Novel, tunable solvatochromic fluorophores as phystiological pH probes. Sci. Rep. 9, 8250 (2019).
Chemical Properties
Storage & Solubility Information
StoragePowder: -20°C for 3 years | In solvent: -80°C for 1 year | Shipping with blue ice.
Solubility Information
DMF: 20 mg/mL
DMSO:PBS (pH 7.2) (1:6): 0.1 mg/mL
DMSO: 20 mg/mL
Ethanol: 1 mg/mL

Calculator

  • Molarity Calculator
  • Dilution Calculator
  • Reconstitution Calculator
  • Molecular Weight Calculator

In Vivo Formulation Calculator (Clear solution)

Please enter your animal experiment information in the following box and click Calculate to obtain the mother liquor preparation method and in vivo formula preparation method:
TargetMol | Animal experimentsFor example, your dosage is 10 mg/kg Each animal weighs 20 g, and the dosage volume is 100 μL . TargetMol | Animal experiments A total of 10 animals were administered, and the formula you used is 5% TargetMol | reagent DMSO+30% PEG300+5% Tween 80+60% ddH2O. So your working solution concentration is 2 mg/mL。
Mother liquor preparation method: 2 mg of drug dissolved in 50 μL DMSOTargetMol | reagent (mother liquor concentration of 40 mg/mL), if you need to configure a concentration that exceeds the solubility of the product, please contact us first.
Preparation method for in vivo formula: Take 50 μL DMSOTargetMol | reagent main solution, add 300 μLPEG300TargetMol | reagent mix well and clarify, then add 50 more μL Tween 80, mix well and clarify, then add 600 more μLddH2OTargetMol | reagent mix well and clarify
For Reference Only. Please develop an appropriate dissolution method based on your laboratory animals and route of administration.
1 Enter information below:
mg/kg
g
μL
2 Enter the in vivo formulation:
% DMSO
%
%Tween 80
%ddH2O

Dose Conversion

You can also refer to dose conversion for different animals. More Dose Conversion

Tech Support

Please see Inhibitor Handling Instructions for more frequently ask questions. Topics include: how to prepare stock solutions, how to store products, and cautions on cell-based assays & animal experiments, etc

Keywords

Related Tags: buy ICAAc | purchase ICAAc | ICAAc cost | order ICAAc