Home Tools
Log in
Cart

CCT020312

Catalog No. T14902   CAS 324759-76-4

CCT020312 is a selective activator of EIF2AK3 and PERK. CCT020312 durably inhibits cell proliferation and elicits the phosphorylation of EIF2A.

All products from TargetMol are for Research Use Only. Not for Human or Veterinary or Therapeutic Use.
CCT020312 Chemical Structure
CCT020312, CAS 324759-76-4
Pack Size Availability Price/USD Quantity
1 mg In stock $ 63.00
5 mg In stock $ 146.00
10 mg In stock $ 255.00
25 mg In stock $ 429.00
50 mg In stock $ 635.00
100 mg In stock $ 883.00
500 mg In stock $ 1,830.00
Bulk Inquiry
Get quote
Select Batch  
Purity: 98.36%
Contact us for more batch information
Biological Description
Chemical Properties
Storage & Solubility Information
Description CCT020312 is a selective activator of EIF2AK3 and PERK. CCT020312 durably inhibits cell proliferation and elicits the phosphorylation of EIF2A.
In vitro In HT29 cells, CCT020312 reduces the P-S608-pRB signal with a linear response between 1.8 and 6.1 μM in a concentration-dependent manner. CCT020312(10 μM) decreases G1/S cyclins D1, D2, E, and A, reduces the CDK catalytic subunit CDK2 and increased the level of the p27KIP1[1].
In vivo In wild-type mice, intraperitoneal injection of CCT020312 (1-5 mg/kg) increases PERK and NRF2 phosphorylation of brain homogenates. In P301S tau transgenic mice, intraperitoneal injection of CCT020312 (2 mg/kg) behaves better in the Morris water maze test[2].
Molecular Weight 650.4
Formula C31H30Br2N4O2
CAS No. 324759-76-4

Storage

Powder: -20°C for 3 years | In solvent: -80°C for 1 year

Solubility Information

DMSO: 90.0 mg/mL (138.4 mM), Sonication is recommended.

TargetMolReferences and Literature

1. Stockwell SR, et al.Mechanism-based screen for G1/S checkpoint activators identifies a selective activator of EIF2AK3/PERK signalling. PLoS One. 2012;7(1):e28568. 2. Bruch J, et al. PERK activation mitigates tau pathology in vitro and in vivo. EMBO Mol Med. 2017 Mar;9(3):371-384.

Related compound libraries

This product is contained In the following compound libraries:
Endoplasmic Reticulum Stress Compound Library Bioactive Compounds Library Max Kinase Inhibitor Library Bioactive Compound Library

Related Products

Related compounds with same targets
SBI-0640756 Vaccarin Azoramide GSK2656157 GP 1a 4E2RCat 2BAct 4E1rcat

TargetMolDose Conversion

You can also refer to dose conversion for different animals. More

TargetMol In vivo Formulation Calculator (Clear solution)

Step One: Enter information below
Dosage
mg/kg
Average weight of animals
g
Dosing volume per animal
ul
Number of animals
Step Two: Enter the in vivo formulation
% DMSO
%
% Tween 80
% ddH2O
Calculate Reset

TargetMolCalculator

Molarity Calculator
Dilution Calculator
Reconstitution Calculation
Molecular Weight Calculator
=
X
X

Molarity Calculator allows you to calculate the

  • Mass of a compound required to prepare a solution of known volume and concentration
  • Volume of solution required to dissolve a compound of known mass to a desired concentration
  • Concentration of a solution resulting from a known mass of compound in a specific volume
See Example

An example of a molarity calculation using the molarity calculator
What is the mass of compound required to make a 10 mM stock solution in 10 ml of water given that the molecular weight of the compound is 197.13 g/mol?
Enter 197.13 into the Molecular Weight (MW) box
Enter 10 into the Concentration box and select the correct unit (millimolar)
Enter 10 into the Volume box and select the correct unit (milliliter)
Press calculate
The answer of 19.713 mg appears in the Mass box

X
=
X

Calculator the dilution required to prepare a stock solution

Calculate the dilution required to prepare a stock solution
The dilution calculator is a useful tool which allows you to calculate how to dilute a stock solution of known concentration. Enter C1, C2 & V2 to calculate V1.

See Example

An example of a dilution calculation using the Tocris dilution calculator
What volume of a given 10 mM stock solution is required to make 20ml of a 50 μM solution?
Using the equation C1V1 = C2V2, where C1=10 mM, C2=50 μM, V2=20 ml and V1 is the unknown:
Enter 10 into the Concentration (start) box and select the correct unit (millimolar)
Enter 50 into the Concentration (final) box and select the correct unit (micromolar)
Enter 20 into the Volume (final) box and select the correct unit (milliliter)
Press calculate
The answer of 100 microliter (0.1 ml) appears in the Volume (start) box

=
/

Calculate the volume of solvent required to reconstitute your vial.

The reconstitution calculator allows you to quickly calculate the volume of a reagent to reconstitute your vial.
Simply enter the mass of reagent and the target concentration and the calculator will determine the rest.

g/mol

Enter the chemical formula of a compound to calculate its molar mass and elemental composition

Tip: Chemical formula is case sensitive: C10H16N2O2 c10h16n2o2

Instructions to calculate molar mass (molecular weight) of a chemical compound:
To calculate molar mass of a chemical compound, please enter its chemical formula and click 'Calculate'.
Definitions of molecular mass, molecular weight, molar mass and molar weight:
Molecular mass (molecular weight) is the mass of one molecule of a substance and is expressed n the unified atomic mass units (u). (1 u is equal to 1/12 the mass of one atom of carbon-12)
Molar mass (molar weight) is the mass of one mole of a substance and is expressed in g/mol.

bottom

Tech Support

Please see Inhibitor Handling Instructions for more frequently ask questions. Topics include: how to prepare stock solutions, how to store products, and cautions on cell-based assays & animal experiments, etc.

Keywords

CCT020312 324759-76-4 Apoptosis PERK CCT-020312 CCT 020312 inhibitor inhibit

 

TargetMol